Commercial 10 HP, 3-Phase-230V (Inlcudes Control Box, DC2530, DC1603 & DRV330) (VacuMaid part CR1525A).
Model CR1525, Ten Horsepower System Power Unit Specifications The vacuum producer is a ten horsepower, regenerative pump and the system includes electrical control box, suction relief valve, primary cyclonic dirt separation canister and secondary fine particle filter canister. Regenerative Pump: Model CR1500C 208 Volt / 30 Amp Model CR1500A 230 Volt / 26 Amp Model CR1500B 460 Volt / 15 Amp Induction Motor, 3 PH, 10 Horsepower, 3,450 RPM 24 Volt Remote Control System, CP1500 control box Maximum Air Flow 405 CFM Sealed Suction 125” H2o in two inch line. Suction Relief Valve Set 90” H2o in two inch line Power Unit Dimensions: Length 24-1/8” Width 18-5/8” Height 21-13/16” Weight 300 lbs., approx. Dirt Canisters Primary Cyclonic Separator, model DC2530 Cyclonic funnel primary, Stand pipe secondary Height 77”, Diameter 25”, Steel Construction Weight approx. 265 lbs. Capacity, approx. 30 Gallons One Safety Screen part # FD2500 Inlet & Outlet Connections 3-1/2” OD Secondary Filter Canister, model DC1603 High Efficiency, reusable bag filter, part number FB1603 Filter Area approx. 7.5 sq ft Capacity approx. 6 gallons Height 29”, Diameter 19” Weight approx. 60 lbs. Inlet & Outlet Connections 3-1/2” OD Suction Relief Valve Regenerative Suction Pumps cannot be allowed to run sealed, without a minimum of 150 CFM or the fan may be damaged. DRV330 suction relief valve is installed in the intake line following the dirt cans and just before the motor Relief comes pre-set from the factory. Installers shall test the valve according to the installation manual and confirm correct operation and suction relief. Power Unit installation Location The VacuMaid power unit system should be installed in area with ventilation and a solid cement floor. The unit must be exhausted to the outside with 3-1/2” metal piping not to exceed 20 ft in length. Area should be large enough for mounting of the suction relief valve and servicing the two dirt canisters. Pump and Canisters The CR1500 pump should be mounted on a solid surface that will not increase or transmit vibration or sound. Vibration isolation materials are recommended. 3-1/2” steel pipe with long radius elbows are recommended. PVC Schedule 40 is an acceptable alternative for the intake, steel pipe is required for the exhaust Electrical Control Box CP1500 control box should be mounted on a wall close to the pump. Electrical Service of the chosen voltage is fed into the control box. 24 Volt remote control wires from intake piping system are fed into the control box. 1.4 Piping and Valves. Pipe or Tube VacuMaid recommends steel pipe for commercial systems. Trunk line, Canisters, Pump and exhaust; 3-1/2” OD with long radius sweep elbows Transitions and drops to the valves: 2-1/8” OD with long radius sweep elbows and Tee’s Exhaust pipes are required to be in 3-1/2” steel Steel Valve mount plates part # SF395 with Aluminum tight 90 Ells part # AF210B for 1-1/2” inlet valves. Mount plates are fastened to partition wall studs in determined locations Stainless steel inlet valves for 1-1/2” hoses with Micro-Switch remote control switches Part number WS832X. Note: The thickness of the wall IE: sheet rock and / or wainscoting must be known to determine The length of the valve stem. Steel pipe couplings and fittings should be connected with “PlioBond” brand cement. Remote Control Wiring Inlet Valves VacuMaid Commercial Systems have a 24 volt on/off remote control system incorporated into the electrical control box. All inlet valves have a microswitch to control the on/off function. Switch is closed when the hose cuff is inserted into the inlet valve. Low volt control circuit is wired to every valve in one looped run and fed into the control box Common or Plenum Rated 18/2 multi strand wiring is used. Low Volt wire is Zip Tied to the pipe Cleaning Attachments (purchased separately) Hose Hose should be commercial grade 1-1/2” OD with a soft cuff on the valve end and curved steel end for the cleaning end. Curved hose wand on cleaning end has 1-1/4” diameter. Wands Two steel 1-1/4” steel wands for each hose Attachments Commercial grade, 1/1/4” Floor Tool, Carpet Tool, Duster Brush, Upholstery Tool, Crevice Tool. Installation Services All central vacuum systems are dependent upon a correct and proper installation. Lindsay Mfg Inc can recommend competent and experienced sub-contractors for this work. Model CR-1525 (C, A, or B–order with letter as end part number) CR-1525C is 208 Voltage, CR-1525A is 230 Voltage, CR-1525B is 460 Voltage 60 Hz. 50 Hz. Induction Motor: …………………………………………… 3Ph, 10HP, 3450 RPM 3 Ph, 8HP, 2850 RPM Voltage: ……………………………………… 208, 230, 460 190-220/380-415 (customer must specify voltage) Amperage (Approx.): ……………………….. 30, 26, 15 17.4-17.2/8.7-8.6 *Electrical Service to Unit: ………………………………. No. 8, No. 10, No. 14 No. 10/14 Pump: ………………………………………………….. Regenerative Airflow @ 3″ Opening (Approx.): ………………………………….. 405 C.F.M. 9.5 CMM Sealed Vacuum (Approx.): ……………………………………………… 125″ H2O 292 cm H2O RECOMMENDED RELIEF VALVE SETTING: ……………………. **90″ H2O **188 cm H2O Dimensions (Approx.): Power Unit: Length: ………………………………………………… 24-1/8″ Width: ………………………………………………….. 18-5/8″ Height: ……………………………………………… 21-13/16″ Shipping Weight (Approx.): ……………………………………………….. 300 lbs. Inlet Connection: ……………………………………………………….. 3-1/2″ I.D. Outlet Connection: ……………………………………………………….. 3-1/2″ I.D. Primary Filter – DC-2530 Filtration: ….. Cyclonic funnel primary, standpipe secondary …………………………………………….. with safety filter. Inlet and Outlet Connections: …………………………………………. 3-1/2″O.D. Diameter: ………………………………………………………………… 25″ Height: ………………………………………………………………… 77″ Capacity (Approx.): ……………………………………………………………………… 30.0 Gal. Shipping weight (Approx.): ……………………………………………….. 265 lbs. Replacement Filter: FD-2500 (2 required) Replacement Bag (3 mil): ………………………………………………….PB-2530 Secondary Filter – DC-1603 Filtration: …………………… High efficiency reusable bag filter. Inlet and Outlet Connections: ………………………………………… 3-1/2″ O.D. Diameter: ………………………………………………………………… 19″ Height: ………………………………………………………………… 29″ Filter Area (Approx.): …………………………………………………… 7.5 Sq. Ft. Shipping Weight (Approx.): …………………………………………………. 60 lbs. Replacement Filter: FB-1603 * Electrical Service to unit should be installed by a licensed electrician. **Preferred Setting NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001). **NOTE: Relief Valve should be set at a preferred setting of 90″ H2O at 60 Hz. and 188 cm H2O at 50 Hz., when possible, use the preferred/recommended settings above. NOTE: You should contact the factory for applications before ordering. NOTE: First five feet of exhaust MUST be metal 3-½” O.D. tubing (SF-3075). CR1500 Series Manual Commercial System Design Guide PDF
Call Central Vacuum Specialists for product help and model guidance.