Commercial 10 HP, 3-Phase-230V (Includes Control Box, DC2600, DC1603 & DRV330) 12-15 users sanding fine dust (VacuMaid part CR1526A).
CR-1526C is 208 Voltage, CR-1526A is 230 Voltage, CR-1526B is 460 Voltage 60 Hz. 50 Hz. Induction Motor: ……………………………………… 3Ph, 10HP, 3450 RPM 3 Ph, 8HP, 2850 RPM Voltage: ………………………………………………….. 208, 230, 460 190-220/380-415 (customer must specify voltage) Amperage (Approx.): ……………………………………………………….. 30, 26, 15 17.4-17.2/8.7-8.6 *Electrical Service to Unit: …………………………………. No. 8, No. 10, No. 14 No. 14 Pump: …………………………………………………… Regenerative Airflow @ 3″ Opening (Approx.): ……………………………………….. 405 C.F.M. 9.5 CMM Sealed Vacuum (Approx.): ………………………………………………….. 125″ H2O 292 cm H2O RECOMMENDED RELIEF VALVE SETTING: ……………………. **90″ H2O **188 cm H2O Dimensions (Approx.): Power Unit: Length: …………………………………………………. 24-1/8″ Width: ………………………………………………….. 18-5/8″ Height: ……………………………………………… 21-13/16″ Shipping Weight (Approx.): …………………………………………………… 300 lbs. Inlet Connection: ……………………………………………………….. 3-1/2″ I.D. Outlet Connection: ……………………………………………………….. 3-1/2″ I.D. Primary Filter – DC-2600 (For use with fine dust ONLY.) Filtration: …………………… Five stage cyclonic with gate valve. Inlet and Outlet Connections: …………………………………………… 3-1/2″ O.D. Diameter: …………………………………………………………………. 25″ Height: …………………………………………………………………. 87″ Radius (including support legs): …………………………………………………… 17″ Capacity (Approx.): ……………………………………………………………. 15 Gal. Shipping Weight (Approx.): …………………………………………………… 265 lbs. Secondary Filter – DC-1603 Filtration: ………………………. High efficiency reusable bag filter. Inlet and Outlet Connections: …………………………………………… 3-1/2″ O.D. Diameter: …………………………………………………………………. 19″ Height: …………………………………………………………………. 29″ Filter Area (Approx.): ……………………………………………………….. 7.5 Sq. Ft. Shipping Weight (Approx.): …………………………………………………….. 60 lbs. Replacement Filter: ………………………………………………………….. FB-1603 *Electrical Service to unit should be installed by a licensed electrician. *Preferred Setting NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001). **NOTE: Relief Valve should be set at a preferred setting of 90″ H2O at 60 Hz. and 188 cm H2O at 50 Hz., when possible, use the preferred/recommended settings above. NOTE: You should contact the factory for applications before ordering. NOTE: First five feet of exhaust MUST be metal 3-½” O.D. tubing (SF-3075). Use with fine dust ONLY, not for use with general cleaning. CR1500 Series Manual
Call Central Vacuum Specialists for product help and model guidance.